Holistic Wellness Store: Sauna, Laser Discs, PEMF, EMF Filters + Bands
Holistic Wellness Store: Sauna, Laser Discs, PEMF, EMF Filters + Bands
PEMF Therapy: PEMF therapy reduces pain, short-term, acute pain and long-term, chronic pain. It relieves pain by blocking pain signals, decreasing inflammation, increasing circulation and increasing cellular flexibility.
PEMF therapy has been used in a variety of ways and research shows that PEMF has been successfully used to treat:
PEMF stands for Pulsed Electromagnetic Field therapy. PEMF devices use a faint magnetic current that is so small it is measured in millionths of an amp. By comparison, a "TENS" unit and most other electro-therapies produce milliamps, 1000 times greater. Your own cells generate a current in the microamp range and this is why you can’t feel it - the current is so low it doesn’t stimulate sensory nerves. Frequency therapy has been in use for over 75 years throughout the world. View Holistic Wellness VIDEOS below.
How does it work? PEMF is a physiological modality that increases ATP (energy) production in the cells of your body. In doing so, this dramatically increases the tissue's healing rate. The almost immediate response to the correct frequencies suggests that other mechanisms are involved as well. The exact effects or changes that result from frequencies have not been proven because no biopsies have been done after PEMF has been applied. Nevertheless, the changes in the tissue are unmistakable; scars will often suddenly soften; trigger points often become less painful; swelling often drains within minutes when the “correct” frequency is applied. In many situations, the changes seen to be long lasting, and in many cases permanent.
Why do the frequencies on the machine need to be changed? Specific frequencies seem to induce specific effects on cells and other tissues. For example, there is a specific frequency for nerves, a different frequency for muscles, another for tendons, etc. PEMF is thought to be good for cells, muscles, tendons, and nearly every aspect of your body. In addition to each tissue having its own unique frequency, there is a specific frequency for each condition. Thus, there is a frequency for inflammation, a different frequency for scars, another to promote secretions, etc. To address the different processes required by the tissue(s) involved, we need to know what is the underlying mechanism or injury.
How do the frequencies work? We believe PEMF works on the principle of biologic resonance. A singer can shatter a glass when the note resonates with the crystal structure of the glass. Pulsed Magnetic frequencies may be able to resonate with biologic tissues when the frequency is correct. Once the tissue is changed and stable, it may stay in the new configuration with proper nutritional support.
Animal research confirms that the frequency to reduce inflammation reduces inflammation by 62% in a mouse model. Prescription drugs reduce inflammation by 45% in the same mouse research. The Frequencies reduced inflammation in other studies almost immediately as well.
When an area of muscle or fascia is injured or damaged either by trauma or repetitive stress, local areas of tenderness or nodules may cause pain or referral pain to other areas of the body. Compression, stretching, and/or strain-counter strain along with frequency therapy, can alleviate or eliminate tissue pain in those injured areas. Your problem may be caused or exacerbated by poor biomechanics. If this is the case, postural advice and exercises for strengthening may be indicated.
You must prepare your body for PEMF Therapy. Adequate hydration is essential for all PEMF treatments. It is advised that you drink 1 quart (four 8oz. glasses) of Purified Water 2 hours prior to your appointment, and 1 more quart of Purified Water after the treatment. If you are not adequately hydrated, you may not see the desired results.
You will not feel the current because it is a small gauss magnetic field. You may experience alteration/reduction in pain or new sensations during the treatment. A sense of calm or sleepiness may occur. This indicates that a frequency is resonating with its intended target.
Do the benefits last? Every person responds individually but the changes to the muscles seem to be long-lasting. About 60% to 80% of the benefits created in one treatment last until the next treatment, about four to seven days.
Your muscles are used to being the way they are and may return to the old configuration if not treated again. Although some people have had permanent changes in one treatment, the average number of treatments depends on the complexity of the problem. We suggest nutritional support tailored to your condition to help create lasting change.
Pulsed Electro-magnetic Field Therapy for Musculoskeletal Pain
July 2023 A retrospective study of veterans finds significant quality-of-life benefits when using PEMF in patients with chronic pain due to MSK disorders. CITE THIS ARTICLE Marovino T, Tassone E. Pulsed Electro-magnetic Field Therapy for Musculoskeletal Pain. Pract Pain Manag. 2023 July/August;23(4). Science of PEMF Pulsed electro-magnetic field (PEMF) science has evolved over the years, and dedicated research on this topic, specifically as it applies to pain management, has been growing. Independent research on PEMF has consistently demonstrated meaningful physiological treatment effects in three areas: pain, inflammation, and perfusion. A systematic review conducted by Paolucci et al sought to identify the relationship between PEMF exposures and symptom mitigation in a heterogenous MSK chronic pain population; 21 RCTs fit the inclusion criteria for their review.
The results of their systematic review supported the contention that PEMF is significantly beneficial for MSK disorders (injury/disease) with the only question being that any one specific protocol could not be identified as being superior to another given the array of protocols used. Similar results have been replicated over many years and many studies with a precise mechanism of action being more elusive to identify. Possible Pathways Basic science studies have identified several biochemical pathways activated by PEMF, some of which are critical in pain and inflammation and could be associated with meaningful epigenetic influences. Pathways activated by PEMF include those activated by calcium ions (Ca2+) and subsequently by nitric oxide (NO) and CGMP at the cellular level.6 Another hypothesis that has been posited is that of induction, whereby PEMF energy can create eddy currents leading to downstream physiochemical effects including nerve stimulation consistent with the gate control theory. Both these hypotheses provide some life science evidence to explain how PEMF exposures might lead to reduction of both pain and inflammation. Bone Stimulation for Osteoarthritis
The use of pulsed EMF is most prevalent in knee osteoarthritis (OA), with research supporting several key therapeutic benefits on knee joint tissue including increasing PEMF signaling that modulates calmodulin-dependent nitric oxide (NO) signaling cascades in particular chondrocytes. PEMF is well known to stimulate bone growth and is used in many of today’s bone stimulation devices. PEMF has been shown to accelerate the removal of inflammatory substances as well as the proliferation of chondrocytes.
The chondroprotective effects of PEMF treatments in knee OA have been shown consistently in studies over the years.10 Perfusion and Oxygenation Effects for Ulcerations Another intriguing physiological effect of PEMF treatment is the increase in perfusion associated with acute PEMF exposure. It is understood that PEMF induces vascularization, which leads to better perfusion and increased oxygenation of tissue which is especially important in the diabetic foot with non-healing ulcerations. However, diabetes-related ulcerations are not the only lesions that improve and resolve with improved perfusion/oxygenation. There is an entire category of ischemic type lesions that could potentially benefit from these effects including neuropathic problems. The key to improved tissue perfusion seems to be the effects PEMF has on circulating levels of NO, which is a known vasodilator substance and, when increased can lead to improved tissue oxygenation and a lowering of blood pressure.
Free Shipping to the Continental USA
Volume Discounts are Available on all our Products.
One-year warranty on parts and labor.
30-day warranty on magnetic discs or laser discs.
Reset Manufacturing will repair or replace, without charge, any defects due to faulty materials or workmanship for one year from the date of purchase. This warranty does NOT cover part failure due to normal wear or abuse. This Warranty does NOT apply to damage caused by others, where repairs have been made or attempted by others. This warranty gives you specific legal rights, which vary in certain states or providences.
If you have a warranty claim to make, please contact Reset Manufacturing at
Reset Manufacturing
36 Lake Rabun Road
Lakemont, Georgia 30552
706-960-9387
Mon-Thurs 9AM - 4PM EST
Devices covered under the warranty will be remitted to Reset Manufacturing
To activate your limited warranty, follow instructions on your Warranty card that you received with your product.
Technical support or Waveonomics software is free for the first 30 minutes. After 30 minutes, you will be charged a flat fee of $50. Please download and install AnyDesk from www.anydesk.com before calling. Call Andy at 706-960-9381 or email: Andy@WellnessPEMF.com for all technical support questions.
What's the source of the frequencies that you use in your PEMF devices?
We use only proven frequencies that we've derived from various sources, but 80% of them were discovered by Dr. Harry Van Gelder and Dr. Albert Abrams, two of the most knowledgeable authorities on frequency healing.
How do I program your devices?
Our devices are programmed with Waveomics™. Download your device's PEMF Software from enclosed flash drive.
My MR7 keeps giving me a timeout error. How can I fix it?
To clear the error, simply press the power button on the MR7 and release it. You should hear a beep which indicates the error has been cleared. After clearing the error, browse to the compiler screen again and try loading the device. Please note, you will still receive an error if you try viewing the files in the MR7 ("View Frequency Files in Device" menu option) after clearing a device error--you will need to return to the compiler screen to reload, instead.
Why can't I update my software when I click on the "Check for Software Updates" button?
If you have an older version of Pulsed Frequency software you will need to update periodically, not every time you open the software. New programs are added to the Magnetic frequency file approximately every 4 months. This applies to all devices. Instructions for updating manually are located in the device user guide. If you need to reinstall software, use the flashdrive included in your device package. If you have an older device that did not receive a flashdrive, please contact marcuscutrone@gmail.com for the software link for your particular device
Do I need to run the device detection program (Detect MR7, etc.) every time I want to load my device?
No. The first time you detect your device, make sure you close the program before unplugging the device and you should not have to run the detection program again.
What do the frequency file name suffixes represent, e.g., "CY", "EST", "NP"?
"CY" programs have Cymatic frequencies added to a Van Gelder set. "EST" programs are established Van Gelder frequency sets. "G" programs are frequency sets that were created by Dr. John Garvey. "NP" programs are nasal probe frequency sets designed to run on the EM272's nasal probes ."PA" programs are phased array programs, which are frequencies that are run in phase with each other. One frequency runs on three magnets while a second frequency runs on another three magnets. When a frequency is run on three magnets in close proximity of each other, the intensity increases five to ten times. These programs are used for deeper penetration.
What are the specs of LED light discs?
The power supplied to each channel of the R21 emitter assembly has an average of 100 mw. That number is the average supplied power to the LEDs and not a measure of emitted light energy. The total peak light flux emitted is 50 milliwatts per channel. That is an estimate for the sum of all 3 Red colors in each channel. Most of this energy is radiated in a 120 degree spacial radiation angle (+/- 60 degree) with the predominant energy radiated perpendicular to the R21 assembly.
I'm looking at another PEMF device that says it runs between 2.5 and 60 microtesla. How many microtesla does your machine produce?
Our machines run between 60 and 120 microtesla. Based on measurements we made in March of 2014 using a calibrated Vernier Software probe, the magnetic field strength from ONE CHANNEL of our devices (such as the EM272, and Joint Pemf,) can be provide is 120 microtesla. The PEAK magnetic energy measured at the surface of the magnetic coil is approximately 240 microtesla. However since we modulate the magnetic field with a 50% duty cycle frequency, that means we generate an AVERAGE magnetic field of 120 microtesla at the surface of the magnetic coil. Magnetic fields drop off rapidly, and with some estimating, at a distance of 0.5 inches from the magnetic coil surface, the PEAK magnetic field at that distance is approximately 60 microtesla. Any measurements at further distances are lost in the noise of the Earth's magnetic field.
What is the magnetic field produced by Wellness PEMF devices?
Using a calibrated magnetic probe made by Vernier, measurements were made on several Wellness PEMF products. In each case the magnetic field was measured under normal operating conditions. Due to the frequency nature and the duty cycle of our products, the readings recorded were adjusted accordingly and taken at peak output. Readings were also adjusted taking away any effect from ambient magnetic fields such as the Earth’s magnetic field. For our battery powered products: such as the EM27, EM272, and the Magnetic Converter... these units produce a magnetic field that is at 50% duty cycle. The magnetic field has a time average at the surface of the case over the emitter of 0.830 Gauss. The instantaneous peak magnetic field is twice that reading due to duty cycle of 1.660 Gauss. When measured at a distance of 1 inch from the surface of the case, the measurement is affected by adjacent coils. If the signal is Phase-Array or asynchronous, under these conditions, the magnetic field ranges from 0.070 to 0.100 Gauss (time average reading) Measurements at further distances are difficult to measure due to the signal levels being comparable with ambient magnetic noise. These measurements were taken at about 50% of the battery charge. The magnetic strength can be +/- 10% of those levels depending on the state of the battery. For Our MR772 product, the magnetic field is somewhat stronger due to the higher current and applied voltage. The magnetic field has a time average at the surface of the case over the emitter of 1.16 Gauss. The instantaneous peak magnetic field is twice that reading due to duty cycle of 2.32 Gauss. When measured at a distance of 1 inch from the emitter case surface, the measurement is affected by adjacent coils. If the signal is Phase-Array or asynchronous, under these conditions, the magnetic field ranges from 0.1 to 0.14 Gauss. The MR7 product has the same instantaneous peak magnetic field as our battery powered units at the surface of the emitter (1.660 Gauss), however due to the varying duty cycle the average magnetic field varies as a function of the programmed frequency. The Duty cycle of the MR7 is the frequency programmed divided by 80,000. So for a 100Hz frequency, the duty cycle is 100/80000= 0.00125 or 0.125% duty cycle. The time average magnetic field of the MR7 is therefore very small. At 100 Hz this would be about 0.001 Gauss.
Why don't we need polarity with Magnetic discs?
Without getting too technical, this is why polarity for magnetics is not needed: The magnetic coils are electro-magnets. Putting a driving current in one direction produces a magnetic field with the North pole perpendicular to the coil top side and a South pole perpendicular to the bottom side. When the current is halted, the collapsing magnetic field yields a South Pole perpendicular to the coil top side and a North pole perpendicular to the bottom side. As a result of this phenomena, as the current pulses are converted to a driving current into the coils, it will produce both North and South pole pulses for every cycle of the input current. Therefore, by converting both polarities of input current to bi-polar magnetic fields, it is not necessary to alter the polarity into the magnetic coils. The CMC unit automatically converts input current of either polarity to a compatible bi-polar magnetic field. As a side advantage, this modification also permits the driving of power into the LED's which requires a uni-directional applied signal for them to function. adding to the effectiveness and utility of the device.
What is the effect of a pulsed magnetic field?
Understanding the effect of a pulsed magnetic field… The response lies in understanding Faradays Law of Induction. A magnetic frequency generates a time varying magnetic field. A magnetic pulse is a magnetic field that is increasing and then decreasing as the magnetic field strength increases and then decreases. A pulsing magnetic field generates a force on an ion, electron, or charged particle by the nature of the changing field strength. If the magnetic field is increasing the force on an ion in one direction and if the field is decreasing the force of the field on the ion in the opposite direction… like a push and then a pull… This is very different than setting up a potential difference between two points and then changing the direction of the potential difference. The push-pull action of reversing the direction of the magnetic field results in specific resonances of biological structures that have charge or exhibit separation of charge within the molecule.
What is the output on the Electrodes for the EM27?
The EM27 outputs either a Positive or Alternating (Positive and Negative) current signal to electrodes that is programmable when the treatment is programmed to be from 25 uA (microamps) to 400 uA. The output frequency that is transmitted is a composite mix of the 7 independent magnetic channels in an inverted spike wave pattern. The programmed current is the PEAK current so the average applied current depends on the mix of frequencies and could have an average current of 50 percent of the programmed peak current.
• DO NOT use any PEMF frequencies on any patient known to be pregnant.
(Frequencies may be used during and after delivery.)
• DO NOT place the contacts over the chest of pacemaker patients.
• DO NOT run current through the brain. Do not place contacts over the ears or eyes.
• Do not use in patient with insulin pumps unless the pump is unplugged from the insulin reservoir. This should avoid any inadvertent signaling that might increase insulin delivery.
• Turn other types of pumps and spinal cord stimulators to the off position during frequency treatment.
• There is not enough experience to know whether it is safe to use frequency therapy in patients who have brain or vagal nerve stimulator implants.
• 13 / This frequency should not be used when there is any injury anywhere on the body more recent than 6 weeks.
• 51/ This frequency should not be used when there is any injury anywhere on the body more recent than 6 weeks.
• 58 / This frequency should not be used when there is any injury anywhere on the body more recent than 6 weeks.
• 3 / This frequency should not be used when there is any injury anywhere on the body more recent than 6 weeks.
• 40 / If this frequency combined with any channel B frequency causes an increase in pain anywhere in the body, check and treat for infection.
• 40 / 10 DO NOT use this frequency on patients with lower extremity muscle spasm or increased tone due to myelopathy. Do not use this frequency when the patient has an active untreated infection. DO use this when the patient has full body pain or spinal sensitization.
• 40 / 116 Do not use this frequency anywhere on the body when there is an infection anywhere on the body.
• 40 / 116 If this frequency causes an increase in pain, check and treat for infection.
• 40 / 89 DO NOT use this frequency when the thalamus is doing its normal job of suppressing pain. Do use this frequency combination in the case of central sensitization or thalamic pain.
• 81 / 10 DO NOTuse this frequency in patients with full body pain secondary to spine trauma. It will make the pain worse. DO use this frequency combination when the patient has lower extremity muscle spasm or increased tone due to myelopathy or mild cerebral palsy.
• 81 / 23 DO NOT use this frequency combination. It may cause unwanted side effects.
• 81 / 17 DO NOT use this frequency combination. It may cause unwanted side effects. Do not use this frequency on an unattended patient.
• 81 / 32 DO NOT use this frequency combination in patients with excess stomach acid, gastritis or gastric disease. It may cause unwanted side effects.
• 81 / 44 DO NOT use this frequency combination. It may cause unwanted side effects. Do not use this frequency on an unattended patient.
• 81 / 64 DO NOT use this frequency combination. It may cause unwanted side effects. Do not use this frequency on an unattended patient.
• 81 / 71 Do NOT use this frequency combination for more than 4 minutes. It may cause unwanted side effects.
• 81 / 89 DO NOT use this frequency combination. It may cause unwanted side effects. Do not use this frequency on an unattended patient.
• 81 / 91 DO NOT run this frequency combination for more than 10 minutes without checking the patient's blood sugar. DO NOT run this frequency combination on an unattended patient.
• 81 / 109 Use this frequency with caution and only under certain circumstances. Do not use this frequency on an unattended patient.
• 81 / 116 DO NOT use this frequency combination in patients with auto-immune disease. Other frequency combinations may be used but not this one.
• 81 / 562 Use this frequency with caution and only under certain circumstances. Do not use this frequency on an unattended patient.
• 94 / 94 This frequency combination may cause dizziness in a small percentage pf people with certain types of vestibular or inner ear injuries. Do not use this frequency for the first time on an unattended patient.
• 284 / 79 DO NOT use this frequency combination when there is a deep vein thrombus
Copyright © 2021 Holistic Wellness Store - All Rights Reserved. Marcus@HolisticWellnessStore.com
850-496-1999
VOLUME DISCOUNTS AVAILABLE CALL MARCUS
**Bitcoin and Ethereum are accepted as payment. Contact Marcus for details.
* Note: For OUTSIDE USA ORDERS please contact, Marcus@HolisticWellnessStore.com for a UPS shipping quote*
SHIPPING IS FREE IN CONTINENTAL USA
We use cookies to analyze website traffic and optimize your website experience. By accepting our use of cookies, your data will be aggregated with all other user data.